Nondosimetric quality assurance of radiotherapy treatment planning system using multi-leaf collimator beam geometry phantom
نویسندگان
چکیده
منابع مشابه
Quality Assurance of External Beam Radiotherapy
'Quality assurance' is all those planned and systematic actions necessary to provide adequate confidence that a product or service will satisfy the given requirements for quality (ISO 9000:1994). As such it is wide ranging, covering all relevant procedures, activities and actions, and hence all groups of staff involved in the process under consideration. 12.1.1.2. Quality assurance in radiother...
متن کاملComparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom
Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...
متن کاملOptimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm
Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...
متن کاملDosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance
Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...
متن کاملOptimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
We consider a problem dealing with the efficient delivery of Intensity Modulated Radiation Therapy (IMRT) to individual patients. IMRT treatment planning is usually performed in three phases. The first phase determines a set of beam angles through which radiation is delivered, followed by a second phase that determines an optimal radiation intensity profile (or fluence map). This intensity prof...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Protection and Environment
سال: 2013
ISSN: 0972-0464
DOI: 10.4103/0972-0464.142386