Nondestructive Measurement of Hemoglobin in Blood Bags Based on Multi-Pathlength VIS-NIR Spectroscopy
نویسندگان
چکیده
منابع مشابه
Nondestructive Measurement of Sugar Content in Navel Orange Based on Vis-NIR Spectroscopy
The Vis-NIR spectroscopy technology was studied on nondestructive measurement of sugar content in navel orange. Three different spectral ranges of 450-1000nm,1000-1800nm and 450-1800nm were selected, respectively and five different spectral pre-processing methods of Standard Normal Variate (SNV), first derivative (FD), second derivative (SD), multiplicative scatter correction (MSC) and smoothin...
متن کاملNon-invasive measurement of blood and tissue parameters based on VIS-NIR spectroscopy
Currently, invasive methods are used to measure the hemoglobin concentration and the most hemoglobin-derivatives, whereby blood is taken from the patient and subsequently analyzed. The noninvasive method presented here allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measur...
متن کاملnondestructive evaluation of internal quality characteristics of kiwifruit by vis/nir spectroscopy
abstract the assessment of ripeness is a major part of quality evaluation and depends on several factors such as soluble solid content (ssc), acidity and firmness. most of the methods that measure these qualities are destructive. so it is essential to develop an efficient and nondestructive method for measuring internal attributes of fruit. the objective of this study was to investigate visible...
متن کاملPear quality characteristics by Vis / NIR spectroscopy.
Recently, non-destructive techniques such as the Vis / NIR spectroscopy have been used to evaluate the characteristics of maturation and quality of pears. The study aims to validate the readings by the Vis / NIR spectroscopy as a non-destructive way to assess the qualitative characteristics of pear cultivars 'Williams', 'Packams' and 'Carrick', produced according to Brazilian conditions. The ex...
متن کاملCerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation.
Near-infrared spectroscopy (NIRS) is a noninvasive optical technique to monitor cerebral oxygen saturation at the bedside. Despite its applicability, NIRS has had limited clinical use because of concerns about accuracy, noted by intersubject variability in slope and intercept of the line between NIRS- and weighted-average arterial-cerebrovenous saturation (SMO2). This study evaluated transcrani...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2018
ISSN: 2045-2322
DOI: 10.1038/s41598-018-20547-2