Non-Selective Magnetoelectric Thermal Radiation Receiver Based on Cadmium Antimonide
نویسندگان
چکیده
منابع مشابه
Thermal emittance and response time of a cesium antimonide photocathode
Measurements of the intrinsic emittance and response time of a Cs3Sb photocathode are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. Photoemission response time is evaluated using a RF deflecting cavity synchronized to a picosecond laser pulse train. We find that Cs3Sb has both small mean transverse energy, 1606 10 meV at 532 nm la...
متن کاملThe non-thermal radiation - Cluster Merger Connection
There is compelling evidence that at least some clusters of galaxies are powerful sources of non-thermal radiation. In all cases where this radiation has been detected, a general trend is that high energy densities of cosmic rays and correspondingly low values of the average magnetic field are required in order to have a self-consistent picture of the multiwavelength observations. Mergers of cl...
متن کاملCapacitively Driven Global Interconnect with Magnetoelectric Switching Based Receiver for Higher Energy Efficiency
We propose capacitively driven low-swing global interconnect circuit using a receiver that utilizes magnetoelectric (ME) effect induced magnetization switching to reduce the energy consumption. Capacitively driven wire has recently been shown to be effective in improving the performance of global interconnects. Such techniques can reduce the signal swing in the interconnect by using a capacitiv...
متن کاملAntimonide-based pN terahertz mixer diodes
High frequency pN heterojunction diodes with cutoff frequencies over 1 THz have been fabricated using narrow bandgap high-mobility semiconductors. The pN heterojunction is composed of a 30 nm thick p-type In0.27Ga0.73Sb alloy and a 130 nm thick In0.69Al0.31As0.41Sb0.59 n-layer. A high-mobility n-type InAs0.66Sb0.34 contact layer is used to connect the mesa diode to a metal Ohmic contact. These ...
متن کاملThermal dose and radiation dose comparison based on cell survival
Background/introduction The biologic dose response curves of thermal dose and absorbed radiation dose have not been compared to each other even though they have both been extensively investigated separately and combined. Although heat and radiation produce cell kill by different biological mechanisms (Thermal dose denatures proteins and the radiation dose causes DNA damage) a comparison of dose...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Metrology and instruments
سال: 2019
ISSN: 2663-9564,2307-2180
DOI: 10.33955/2307-2180(5)2019.32-36