Non-Rigid Point Set Registration via Adaptive Weighted Objective Function
نویسندگان
چکیده
منابع مشابه
Non-rigid point set registration: Coherent Point Drift
We introduce Coherent Point Drift (CPD), a novel probabilistic method for nonrigid registration of point sets. The registration is treated as a Maximum Likelihood (ML) estimation problem with motion coherence constraint over the velocity field such that one point set moves coherently to align with the second set. We formulate the motion coherence constraint and derive a solution of regularized ...
متن کاملStochastic Optimization for Rigid Point Set Registration
In this paper we propose a new method for pairwise rigid point set registration. We pay special attention to noise robustness, outlier resistance and global optimal alignment. The problem of registering two point clouds in space is converted to a minimization of a nonlinear cost function. We propose a cost function that aims to reduce the impact of noise and outliers. Its definition is based on...
متن کاملDensity Adaptive Point Set Registration
Probabilistic methods for point set registration havedemonstrated competitive results in recent years. Thesetechniques estimate a probability distribution model of thepoint clouds. While such a representation has shownpromise, it is highly sensitive to variations in the den-sity of 3D points. This fundamental problem is primar-ily caused by changes in the sensor location...
متن کاملRigid point registration circuits
In 1996 Freeborough proposed a method for estimating target registration error (TRE) in the absence of ground truth. In his approach, a circuit of registrations is performed using the same registration method on multiple views of the same object: 1 to 2, 2 to 3, ..., NC –1 to NC , and NC to 1 where NC is at least three and the last registration completes the circuit. Any difference between the ...
متن کاملValidation of non-rigid point-set registration methods using a porcine bladder pelvic phantom.
The problem of accurate dose accumulation in fractionated radiotherapy treatment for highly deformable organs, such as bladder, has garnered increasing interest over the past few years. However, more research is required in order to find a robust and efficient solution and to increase the accuracy over the current methods. The purpose of this study was to evaluate the feasibility and accuracy o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2018
ISSN: 2169-3536
DOI: 10.1109/access.2018.2883689