Non-local Methods with Shape-Adaptive Patches (NLM-SAP)
نویسندگان
چکیده
منابع مشابه
Mesh saliency with adaptive local patches
3D object shapes (represented by meshes) include both areas that attract the visual attention of human observers and others less or not attractive at all. This visual attention depends on the degree of saliency exposed by these areas. In this paper, we propose a technique for detecting salient regions in meshes. To do so, we define a local surface descriptor based on local patches of adaptive s...
متن کاملAdaptive Multilevel Methods with Local Smoothing
A multilevel method on adaptive meshes with hanging nodes is derived. Smoothing is restricted to the interior of the subdomains refined to the current level, thus has optimal computational complexity. Its convergence rates are the same as for the the non-adaptive version. We discuss the implementation in a general finite element code at the example of the deal.II library.
متن کاملScale-adaptive Local Patches for Robust Visual Object Tracking
This paper discusses the problem of robustly tracking objects which undergo rapid and dramatic scale changes. To remove the weakness of global appearance models, we present a novel scheme that combines object’s global and local appearance features. The local feature is a set of local patches that geometrically constrain the changes in the target’s appearance. In order to adapt to the object’s g...
متن کاملAirfoil Shape Optimization with Adaptive Mutation Genetic Algorithm
An efficient method for scattering Genetic Algorithm (GA) individuals in the design space is proposed to accelerate airfoil shape optimization. The method used here is based on the variation of the mutation rate for each gene of the chromosomes by taking feedback from the current population. An adaptive method for airfoil shape parameterization is also applied and its impact on the optimum desi...
متن کاملSR-NLM: A sinogram restoration induced non-local means image filtering for low-dose computed tomography
Radiation dose has raised significant concerns to patients and operators in modern X-ray computed tomography (CT) examinations. A simple and cost-effective means to perform a low-dose CT scan is to lower the milliampere-seconds (mAs) as low as reasonably achievable in data acquisition. However, the associated image quality with lower-mAs scans (or low-dose scans) will be unavoidably degraded du...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Mathematical Imaging and Vision
سال: 2011
ISSN: 0924-9907,1573-7683
DOI: 10.1007/s10851-011-0294-y