Non-linear modelling of Ferro casting ductile shear key of L-Shaped concrete blocks with epoxy joint using Midas FEA

نویسندگان

چکیده

As cast iron with 10-15% of graphite, Ferro Casting Ductile (FCD) Iron material has better mechanical properties than the ones from Grey Cast Iron. Moreover, it is also close to Carbon Steel’s properties. Regarding this condition, FCD potential be used as a shear key, specifically, joint precast segmental concrete bridges. The objective paper study behavior applied key on wet using epoxy. To do so, three-dimensional non-linear numerical modeling Midas FEA was conducted two L-shaped blocks connected by couple representing bridge system. Between these concrete, epoxy adhesive applied. Both and keys 50% scale original geometries were used. constitutive each obtained previous test results literatures. Loading applications performed in directions, vertical load represent deck horizontal prestressing force. Load bearing capacity increases along increase load. Non-linear analysis show discrepancy comparing experimental ones, deviation reaches more 7%.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

non-linear study of various slit shear walls in steel structures

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

15 صفحه اول

Analysis of Thin-Walled Steel Sections Filled with Concrete Using Non-Linear Finite Element Method

Being economical and performing well under cyclic loads, steel sections filled with concrete have been widely used in structural buildings. Extensive studies and experiments have been conducted to investigate the influence of different parameters and loadings on the behavior of these structural components. Based on the data available from previous experiments and studies, this paper discusses t...

متن کامل

Analysis of Thin-Walled Steel Sections Filled with Concrete Using Non-Linear Finite Element Method

Being economical and performing well under cyclic loads, steel sections filled with concrete have been widely used in structural buildings. Extensive studies and experiments have been conducted to investigate the influence of different parameters and loadings on the behavior of these structural components. Based on the data available from previous experiments and studies, this paper discusses t...

متن کامل

detection of volatile compounds of medicinal plants with some nano-sorbents using modified or new methodologies and investigation of antioxidant activity of their methanolic extracts

in this work, a novel and fast method for direct analysis of volatile compounds (davc) of medicinal plants has been developed by holding a filament from different parts of a plant in the gc injection port. the extraction and analysis of volatile components of a small amount of plant were carried out in one-step without any sample preparation. after optimization of temperature, extraction time a...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: 3C Tecnología

سال: 2021

ISSN: ['2254-4143', '2605-3853']

DOI: https://doi.org/10.17993/3ctecno/2021.v10n3e39.101-117