Non-invasive cardiac output monitoring.
Outcomes in the management of critically ill patients may be improved using goal-directed peri-operative haemodynamic monitoring. A conservative approach may no longer be acceptable but in view of the significant morbidity associated with balloon tipped flow directed pulmonary artery catheters a non-invasive approach would be preferable. In this review we consider the different non-invasive tec...
متن کاملNon-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery.
PURPOSE This study was to compare noninvasive measurement of cardiac output (CO) using a novel Doppler technique with invasive CO measurements in the postcardiac surgical intensive care unit. DESCRIPTION Thirty-six patients (67.2 +/- 10 years, New York Heart Association functional class 3.1 +/- 0.3) undergoing coronary revascularization were prospectively examined postoperatively. One hundred...
متن کاملNon-Invasive Monitoring of Cardiac Output in Critical Care Medicine
Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of ac...
متن کاملUltrasonic Cardiac Output Measurement for Non- Invasive Cardiac Output Monitoring: Update and Lit- Erature Review
In this article, we review use and clinical utility of the Ultrasonic Cardiac Output Monitor, manufactured in Australia, which was first introduced clinically in 2001. It is non-invasive, requires only a low cost and allows for bedside examination, all of which make this tool potentially useful for patients in emergency departments and intensive care units. Its uses include triage, differential...
متن کاملMonitoring non-invasive cardiac output and stroke volume during experimental human hypovolaemia and resuscitation.
BACKGROUND Multiple methods for non-invasive measurement of cardiac output (CO) and stroke volume (SV) exist. Their comparative capabilities are not clearly established. METHODS Healthy human subjects (n=21) underwent central hypovolaemia through progressive lower body negative pressure (LBNP) until the onset of presyncope, followed by termination of LBNP, to simulate complete resuscitation. ...