Non-integral AC Capacitor Voltage Calculation Method for Shunt Hybrid Active Power Filter

نویسندگان

چکیده

This paper introduces a novel non-integral method for calculating AC capacitor voltage in shunt hybrid active power filters (SHAPFs). These commonly use passive (PPFs) that can introduce containing harmonics into the capacitor, leading to overvoltage situations be dangerous. To avoid accidents due overvoltage, it is necessary monitor continuously. The proposed enables calculation of across using only sensor available SHAPF, without requiring additional sensors. By avoiding integration calculate voltage, effectively mitigates errors DC offset inflows. effectiveness was verified through simulations and actual experiments. Results demonstrate improves accuracy by approximately 1.93[%] when compared general method. represents significant advancement SHAPFs, providing an effective means reducing risks, sensors or costly equipment.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Analysis of Flying Capacitor Multilevel Inverter Based Shunt Active Power Filter to Voltage Deregulation of Non Linear Loads

This paper main intents to present a flying capacitor multilevel inverter based shunt active power filter(APF) with Sigma-Delta modulation. A multilevel Sigma-Delta modulation(SDM) control can be applied to control power section of APF intention to reducing sensitivity to flying capacitor voltage deregulation and mending modulator performance. In these control section of APF perfect harmonic ca...

متن کامل

Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

متن کامل

Modelling of Three-phase Shunt Hybrid Active Power Filter

The three-phase Shunt hybrid APF topology for harmonic mitigation in low and medium voltage power distribution systems consists of a VSI based three phase shunt active filter (SAF) and tuned passive filters (TPF) connected in parallel with the load. This chapter discusses the modelling of shunt active filter and design of filter interfacing inductor, DC bus capacitor, tuned passive filters. It ...

متن کامل

Shunt Active Filter for Power Quality Improvement

This paper describes the development of a low cost shunt active power filter with digital control, which allows dynamic power factor correction and both harmonics and zero-sequence current compensation. The active filter controller is based on the instantaneous power theory (p-q theory) and was implemented using a standard 16 bits microcontroller. The p-q theory is introduced followed by the pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2023

ISSN: ['2169-3536']

DOI: https://doi.org/10.1109/access.2023.3291073