Non-destructive Measurement of Complex Permittivity of Board Type Dielectric Sample using Rectangular Cavity Resonator
نویسندگان
چکیده
منابع مشابه
Complex permittivity measurements at Ka-Band using rectangular dielectric waveguide
The rectangular dielectric waveguide (RDWG) technique has been developed for the determination of the dielectric constant of materials from effective refractive index measurements in the Q and W bands. This paper describes the use of an optimization method in conjunction with the RDWG technique for the determination of both the dielectric constant and loss tangent of materials at Ka-Band. The e...
متن کاملMeasurement of Complex Permittivity using Planar Resonator sensor
A Microstrip loop resonator sensor designed to determine the dielectric constant of a liquid is proposed. The resonator sensor designed for 1GHZ for different structure of loop is described. The sensor is implemented using planar microstrip technology. A dielectric material is placed above microstrip ring resonator. As a consequence the near field of the resonator interacts with the material un...
متن کاملBroadband coaxial cavity resonator for complex permittivity measurements of liquids
A novel cavity perturbation technique using coaxial cavity ruonators for the measurement of complex permittivity of liquids is presented. The method employs two types of resonators (Resonator I and Resonator ll). Resonator l operates in the fre quency range 600 MHZ-7 CH2 and resonator ll operates in the frequency range 4 Gliz-14 CH2. The introduction of the capillary tube filled wit? the sampl...
متن کاملFractional Rectangular Cavity Resonator
Fractional curl operator has been used to derive solutions to the Maxwell equations for fractional rectangular cavity resonator. These solutions to the Maxwell equations may be regarded as fractional dual solutions. Behavior of field lines and surface current density in fractional cavity resonator have been investigated with respect to the fractional parameter. Fractional parameter describes th...
متن کاملA Modified Formula for Microwave Measurement of Dielectric Loss Using a Closed Cylindrical Cavity Dielectric Resonator
This paper provides a modified formula for calculating dielectric loss of dielectric resonator of working in TE01δ mode in closed cavity. The measurement system is divided into six regions. Based on analyzing the formula of loss tangent published in literatures, a quality factor of a substrate is created, and a modified formula is proposed. Validating the modified formula, with three substrates...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Fundamentals and Materials
سال: 2002
ISSN: 0385-4205,1347-5533
DOI: 10.1541/ieejfms.122.748