Non-contact torque sensor based on magnetostrictive Fe<sub>30</sub>Co<sub>70</sub> alloy

نویسندگان

چکیده

A non-contact torque sensor based on a magnetostrictive Fe30Co70 rod wound with an excitation coil and pickup is proposed in this paper. In the magnetic field range 0–30 kA/m, changing rate linearity of magnetostriction loading samples are significantly improved after heat treatment. Maximum 103 ppm annealed sample parallel direction, while its tensile strength allowable shear stress 608 194.56 MPa, respectively. According to mathematical model presented work, there linear relationship between output voltage torque. An apparent increase induced signal (peak voltage) 48.23 mV observed as increases 20 Nm case applying sinusoidal signals. addition, experimental results consistent calculated values within 0–16 Nm, good sensitivity 2.87 mV/Nm obtained. This work shows prospect alloy for sensing appropriate property no orientation requirement.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Study of a Handrim-Activated Power-Assist Wheelchair Based on a Non-Contact Torque Sensor

Demand for wheelchairs is increasing with growing numbers of aged and disabled persons. Manual wheelchairs are the most commonly used assistive device for mobility because they are convenient to transport. Manual wheelchairs have several advantages but are not easy to use for the elderly or those who lack muscular strength. Therefore, handrim-activated power-assist wheelchairs (HAPAW) that can ...

متن کامل

Temperature Distribution Sensor Based on Magnetostrictive Delay Lines

In this paper we propose a new family of temperature distribution sensors based on the magnetostrictive delay line technique. An array of parallel conductors is set orthogonal to the delay line and used for pulsed current transmission. coil is set around the one end of the delay line in order to receive the magneto-elastic pulses. A platinum wire or a thermistor is electrically connected to the...

متن کامل

Non-contact breath sensor based on a Doppler detector

Respiratory activity is an important parameter for observation of human body activity. A normal adult has a respiratory rate of 12–15 breaths/min in normal conditions. Breath sensor based on non-contact Doppler detector allows for the measurement and detection and the absence of the breathing action, which may cause death in a few minutes. The monitoring and detection of some respiratory abnorm...

متن کامل

Flexible Foot/Ankle Based on PKM with Force/Torque Sensor for Humanoid Robot

This paper describes the development of a novel humanoid robot foot/ankle based on an orientation Parallel Kinematic Mechanism for intelligent and flexible control. With three identical Universal-Prismatic-Spherical prismatic-actuated limbs and a central Universal-Revolute passive limb, the PKM can perform three degrees of freedom rotation motions. In order to enable the humanoid robot safely t...

متن کامل

Design and Construction of a Novel Tactile Sensor for Measuring Contact-Force, Based on Piezoelectric Effect

In this paper, design and construction of a tactile sensor for measuring contact-force is presented. Mechanism of measuring contact-force in this tactile sensor is based on impedance changing of piezoelectric crystal and voltage of different points in circuit as a result of applying force on the crystal. By considering a specific point in the circuit and recording the changes of its voltage, ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: AIP Advances

سال: 2022

ISSN: ['2158-3226']

DOI: https://doi.org/10.1063/5.0081248