Noise Exposure on Human Cochlea During Cochleostomy Formation Using Conventional and a Hand Guided Robotic Drill
نویسندگان
چکیده
منابع مشابه
Feasibility Study of a Hand Guided Robotic Drill for Cochleostomy
The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper...
متن کاملRobotic-guided minimally-invasive cochleostomy: first results
Due to increasing claims on high precision surgery, robotic assistance is becoming an emerging and highly demanded technology. Especially in surgical procedures in regions with complex anatomy mechatronical devices could help prevent iatrogen damaging of risk structures. In Otolaryngology particular cochlear implantation is a procedure characterized by a high degree of complexity and required a...
متن کاملsimulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water
abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...
Investigating the Effects of Exposure to Continuous White Noise on SLC26A4 Gene Expression Levels in Male Rat Cochlea
Background and purpose: Irreversible damage to the inner ear is known as noise-induced hearing loss (NIHL). Exposure to excessive noise can affect the expression of genes in molecules involved in development of NIHL. SLC26A4 gene or PDS is responsible for causing both syndromic and non-syndromic deafness and is located at DFNB site. The aim of this study was to investigate the expression level ...
متن کاملSemiautomatic Cochleostomy Target and Insertion Trajectory Planning for Minimally Invasive Cochlear Implantation
A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n = 10 ears). Cochleostomy tar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Otology & Neurotology
سال: 2020
ISSN: 1531-7129,1537-4505
DOI: 10.1097/mao.0000000000002699