NO2 Detection Using Microcantilever Based Potentiometry

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NO2 Detection Using Microcantilever Based Potentiometry

A highly sensitive and novel sensor platform for gases and volatile chemicals using microcantilever based potentiometry is reported. A resonant cantilever is used to detect the changes in surface work functions of functionalized substrates caused by adsorption of target gas molecules. Surface work function (SWF) changes were measured for different functionalization layers made of transition met...

متن کامل

Detection of Pb2+ using a hydrogel swelling microcantilever sensor.

Hydrogels containing benzo-18-crown-6 were used to modify microcantilevers for measurements of the concentration of Pb2+ in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various Pb2+ concentrations as the result of a swelling of the hydrogels. It was found that a concentration of 10(-6) M Pb2+ can be detected using this technology. Ot...

متن کامل

Detection of CrO4(2-) using a hydrogel swelling microcantilever sensor.

Hydrogels containing various mounts of tetraalkylammonium salts were used to modify microcantilevers for measurements of the concentration of CrO4(2-) in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various CrO4(2-) concentrations as a result of swelling or shrinking of the hydrogels. The microcantilever deflection as a function of t...

متن کامل

Detection of Cd(II) using antibody-modified microcantilever sensors.

This work demonstrated the feasibility of detecting divalent Cd(II) ions using antibody-modified microcantilever (MCL) sensors. Different surface modification methods were compared and multilayer approach was found superior than others for MCL surface modifications for antibody-based Cd(II) sensor development. When the Cd(II)-EDTA complex sample is injected into the fluid cell where the MCL is ...

متن کامل

MicroCantilever (MC) based nanomechanical sensor for detection of molecular interactions

Specific aims of this study are to investigate the mechanism governing surface stress generation associated with chemical or molecular binding on functionalized microcantilevers. Formation of affinity complexes on cantilever surfaces leads to charge redistribution, configurational change and steric hindrance between neighboring molecules resulting in surface stress change and measureable cantil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2008

ISSN: 1424-8220

DOI: 10.3390/s8117144