No-patch 23-gauge vitrectomy under topical anesthesia: A pilot study
نویسندگان
چکیده
منابع مشابه
A Comparison of Topical or Retrobulbar Anesthesia for 23-Gauge Posterior Vitrectomy
Background. To compare the efficacy and safety of topical anesthesia versus retrobulbar anesthesia in 23-gauge vitreoretinal surgery. Materials and Methods. A total of 63 patients scheduled for 23 G posterior vitrectomy without scleral buckling procedures were included in the study. The patients were randomly assigned to receive either topical (Group 1, n = 31) or retrobulbar anesthesia (Group ...
متن کامل27-Gauge Vitrectomy for Symptomatic Vitreous Floaters with Topical Anesthesia
PURPOSE Traditionally acceptable methods of anesthesia for vitrectomy surgery are quite varied. However, each of these methods has its own potential for complications that can range from minor to severe. The surgery procedure of vitrectomy for symptomatic vitreous floaters is much simpler, mainly reflecting in the nonuse of sclera indentation, photocoagulation, and the apparently short surgery ...
متن کاملComparison of the 20-Gauge Conventional Vitrectomy Technique with the 23-Gauge Releasable Suture Vitrectomy Technique
PURPOSE To compare the efficacy of the transconjunctival releasable suture technique for pars plana vitrectomy using 23-gauge (23G) instruments versus the conventional 20-gauge (20G) technique. METHODS A retrospective and interventional case series was consecutively performed for 199 eyes of the 192 patients that were a part of this study. Clinical data were reviewed retrospectively regarding...
متن کاملFactors influencing self-sealing of sclerotomy performed under gas tamponade in 23-gauge transconjunctival sutureless vitrectomy
BACKGROUND The purpose of this study was to investigate factors influencing self-sealing of sclerotomy performed under gas tamponade in 23-gauge transconjunctival sutureless vitrectomy. METHODS This study was a retrospective review of 84 patients (84 eyes) who underwent 23-gauge transconjunctival sutureless vitrectomy under gas tamponade by a single surgeon. At the end of surgery, the sclerot...
متن کاملUnexplained postoperative retinal hemorrhage after 23-gauge sutureless vitrectomy
We report five cases of unexplained retinal hemorrhage after 23-gauge sutureless vitrectomy. A 23-gauge sutureless vitrectomy was performed for four cases of macular holes (MH) and one case of macular hole retinal detachment (MHRD). Retinal hemorrhages were observed on the first day after surgery and disappeared within several months without leaving any recognizable damage. We speculate that th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Ophthalmology
سال: 2011
ISSN: 0301-4738
DOI: 10.4103/0301-4738.77038