Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN.

In the present paper, a solid phase extraction system for separation and preconcentration of nickel (ng g(-1)) in saline matrices is proposed. It is based on the adsorption of nickel(II) ions onto an Amberlite XAD-2 resin loaded with 1-(2-pyridylazo)-2-naphthol (PAN) reagent. Parameters such as the pH effect on the nickel extraction, the effect of flow rate and sample volume on the extraction, ...

متن کامل

Preconcentration of lead with Amberlite XAD-2 and Amberlite XAD-7 based chelating resins for its determination by flame atomic absorption spectrometry.

Four chelating matrices prepared by coupling Amberlite XAD-2 with chromotropic acid (AXAD-2-CA or 1), pyrocatechol (AXAD-2-PC or 2) and thiosalicylic acid (AXAD-2-TSA or 3) through azo spacer and impregnation of Amberlite XAD-7 with xylenol orange (AXAD-7-XO or 4) have been studied for enrichment of lead(II). All the four resins quantitatively sorb Pb(II) at pH 3.0-8.0 when the flow rate is mai...

متن کامل

Determination of some trace metals by FAAS after solid-phase extraction with amberlite XAD-1180/TAN chelating resin.

A new chelating resin was synthesized by immobilizing 1-(2-thiazolylazo)-2-naphthol through the -N=N- group on Amberlite XAD-1180. The resin was used for the preconcentration of Cd(II), Co(II), Cu(II), Mn(II), Ni(II), and Pb(II) ions and their determination by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters, such as the pH, volume of the sample, flow ra...

متن کامل

Adsorption characteristics of as(III) and as(V) with titanium dioxide loaded Amberlite XAD-7 resin.

The adsorption characteristics of As(V) and As(III) on titanium dioxide loaded Amberlite XAD-7 resin have been studied. The resin was prepared by impregnation of Ti(OC2H5)4 followed by hydrolysis with ammonium hydroxide. Batch adsorption experiments were carried out as a function of the pH, shaking time and the concentration of As(V) and As(III) ions. The resin showed a strong adsorption for As...

متن کامل

Determination of cobalt in urine by FI-ICP-AES with online preconcentration.

A method for the preconcentration and determination of cobalt in human urine samples was developed. The online preconcentration and determination were attained using inductively coupled plasma atomic emission spectromety (ICP-AES) coupled to a flow injection (FI) method. Cobalt was retained on an Amberlite XAD-7 resin as cobalt-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex at pH 9.5. Co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Talanta

سال: 1999

ISSN: 0039-9140

DOI: 10.1016/s0039-9140(98)00339-7