New Structure Design for 126kV HV Vacuum Circuit Breaker
نویسندگان
چکیده
منابع مشابه
Optimal Design of a Permanent Magnetic Actuator for Vacuum Circuit Breaker using FEM
This paper presents the characteristic analysis and the optimal design of a permanent magnetic actuator (PMA) for a vacuum circuit breaker (VCB) using a two-dimensional finite element analysis. The purpose of this research about a PMA is to minimize the breaking time and the volume of the permanent magnet within the limits of the holding force and maximum current in the coil. The conjugate grad...
متن کاملFault Diagnosis Method of HV Circuit Breaker Based on Wavelets Neural Network
Fault diagnosis of HV circuit break has been investigated extensively as an important device in the field of power system. In view of the shortcoming of the traditional neural network, such as the slow convergence rate and the local minimum easy to form, fault diagnosis method of HV circuit breaker is proposed to remedy the defects of traditional neural network based on wavelets neural. This me...
متن کاملA Model-Based Fault Detection Framework for Vacuum Circuit Breaker by Trip Coil Analysis
Vacuum circuit breaker becomes more and more complicated, integrated, high-speed and intellectualized. To insure vacuum circuit breaker in its good conditions, the function of fault diagnosis gets more important than before in the process of repairing. This paper is addressed a modelbased fault detection framework for vacuum circuit breaker by trip coil analysis. At first, the electromagnetic m...
متن کاملAnalysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure
Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...
متن کاملReliability modeling and data analysis of vacuum circuit breaker subject to random shocks
The electrical substation components are often subject to degradation due to over-voltage or over-current, caused by a short circuit or a lightning. A particular interest is given to the circuit breaker, regarding the importance of its function and its dangerous failure. This component degrades gradually due to the use, and it is also subject to the shock process resulted from the stress of iso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Control and Automation
سال: 2014
ISSN: 2005-4297,2005-4297
DOI: 10.14257/ijca.2014.7.12.01