New Methods of Energy Efficient Radon Mitigation
نویسندگان
چکیده
منابع مشابه
Energy Losses and Operational Costs of Radon Mitigation Systems
Energy losses and operational costs of radon mitigation systems in typical locations within the various heating zones in the USA have been calculated that include a modeling of seasonal and daily temperature variations. Two types of energy losses are compared with the electrical energy consumption for various ventilators that will be presented graphically. These energy losses will also be compa...
متن کاملon the comparison of keyword and semantic-context methods of learning new vocabulary meaning
the rationale behind the present study is that particular learning strategies produce more effective results when applied together. the present study tried to investigate the efficiency of the semantic-context strategy alone with a technique called, keyword method. to clarify the point, the current study seeked to find answer to the following question: are the keyword and semantic-context metho...
15 صفحه اولRadon Mitigation in Blocks of Flats
The average indoor radon concentration in Finnish flats is 80 Bq/m3. Typically walls have been made using concrete elements. Building materials are the dominant source of indoor radon. However, in the flats of the lowest floor, with a floor slab in direct ground contact, the main source of radon is often the inflow of radon bearing soil air. The number of these ground contact flats is less than...
متن کاملMitigation of ineffective measures against radon.
Reasons of low effectiveness of radon remedial measures have been studied on several unsuccessfully remediated houses. Based on the thorough analysis, factors responsible for failures are clarified. The possibilities of how to improve the effectiveness of installed measures are also discussed. Experience in this field is documented by several examples of additionally mitigated houses. After app...
متن کاملComplex Radon Mitigation of a Large Building
"Home Plate", a combination bar, grill, and recreation center, is an 8000 ft2 single-story slab-ongrade building with a partial basement. Radon testing of each ground-contact room found elevated radon levels in seven of eight rooms (5.6 pCi/L to 13.4 pCi/L). Mitigation diagnostics determined that the installation of three active soil depressurization (ASD) systems would reduce the levels to <4 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Health Physics
سال: 1995
ISSN: 0017-9078
DOI: 10.1097/00004032-199505000-00009