New method for intraocular lens power calculation using a rotating Scheimpflug camera in eyes with corneal refractive surgery
نویسندگان
چکیده
منابع مشابه
Intraocular Lens Power Calculation after Corneal Refractive Surgery
PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...
متن کاملCorneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery.
PURPOSE To evaluate the accuracy of central corneal power measurements by Scheimpflug imaging (Pentacam) for eyes that had corneal refractive surgery. METHODS This study comprised two groups: a pilot group of 100 eyes with prior hyperopic or myopic LASIK that did not have cataract surgery, and a test group of 41 eyes with prior radial keratotomy (RK) and cataract surgery. In the pilot group, ...
متن کامل[Intraocular lens power calculations in eyes with previous corneal refractive surgery].
Results of intraocular lens power calculation were lower than actual required power in eyes with previous corneal refractive surgery because the inaccurate readings of corneal power obtained from standard keratometry. This causes the unacceptable hyperopia after cataract surgery. With increasing of population undergone excimer laser refractive surgery, this problem will be an obvious problem in...
متن کاملCalculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery.
PURPOSE To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. METHODS Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic...
متن کاملcomparison of different methods for intraocular lens power calculation after corneal refractive surgery
with the increasing number of keratorefractive surgical procedures in the past years, an increasing number of cataract operations in eyes with previous keratorefractive surgery is anticipated. although cataract extraction seems to be feasible without major technical obstacles, intraocular lens (iol) power calculation remains problematic. insertion of measured k-readings after myopic photorefrac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2020
ISSN: 2045-2322
DOI: 10.1038/s41598-020-65827-y