New Ergonomic Design Criteria for Handles of Laparoscopic Dissection Forceps
نویسندگان
چکیده
منابع مشابه
New ergonomic design criteria for handles of laparoscopic dissection forceps.
BACKGROUND The shape of laparoscopic instrument handles can cause physical discomfort. This problem may be ascribed to a lack of standards for instrument design. In this study, new ergonomic requirements for the design of laparoscopic dissection forceps were created. Three representative handles (a Karl Storz [click-line] scissors handle, an Access Plus scissors handle, and an Aesculap cylindri...
متن کاملUsing Ergonomic Rules for Evaluation by Linguistic Ergonomic Criteria
Heuristic Evaluation is a well established method for evaluating a user interface (UI) of an interactive application [1]. This method belongs to the class of informal evaluation methods since the evaluation is performed on the basis of evaluator expertise and knowledge. One characteristic of heuristic evaluation is to guide evaluators by providing them a small set of predefined heuristics rathe...
متن کاملinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Laparoscopic Removal of an Artery Forceps
Numerous foreign bodies, such as surgical gauze, pads and instruments, and other items, have been left behind in the abdominal cavity during open surgeries. These have been traditionally removed at redo open surgeries. Here we describe a case of an artery forceps left behind at a previous surgery (open cholecystectomy and appendicectomy) performed 5 years earlier that was removed by laparoscopy.
متن کاملUse of Johan forceps as endoloop pushers for laparoscopic appendicectomy
Figure 2 Clinical photograph demonstrating the long distal drain still protruding after closure of the arthrotomy (Fig 1). Close the arthrotomy from proximal to distal, leaving the distal end protruding (Fig 2). As you reach the end of the wound where the drain exits the arthrotomy, withdraw the drain to length. As the drain withdraws easily, you can be sure that it has not been sutured into th...