New Equation to Estimate Patient Surface Absorbed Dose from Effective X-ray Energy
نویسندگان
چکیده
منابع مشابه
Patient effective dose evaluation for chest X-ray examination in three digital radiography centers
Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...
متن کاملPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کاملApplication of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology
Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...
متن کاملParameters affecting the X-ray dose absorbed by macromolecular crystals.
The lifetime of a macromolecular crystal in an X-ray beam is assumed to be limited by the absorbed dose. This dose, expressed in Gray (Gy = J kg(-1)), is a function of a number of parameters: the absorption coefficients of the constituent atoms of the crystal, the number of molecules per asymmetric unit, the beam energy, flux, size and profile, the crystal size, and the total irradiation time. ...
متن کاملpatient effective dose evaluation for chest x-ray examination in three digital radiography centers
background: the radiation doses resulting from diagnostic x-ray examinations are routinely measured in terms of entrance surface dose (esd) and effective dose (ed). in this study, for the purpose of radiation protection, the radiation doses received from digital chest x-ray examination were evaluated in terms of esd and ed. material and methods: the ed was calculated by using the mcnp monte car...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 2001
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00001357708