New electronic apex locator Romiapex A-15 presented accuracy for working length determination in permanent teeth

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth

OBJECTIVES Correct determination of working length is an important step for success of endodontic therapy. Conventional radiography has limitations in providing the accurate location of apical foramen. For this reason, electronic apex locators (EALs) were developed to shorten the treatment time and decrease the radiation dose. The aim of this study was to evaluate the accuracy of Root ZX EAL fo...

متن کامل

accuracy of an electronic apex locator for working length determination in primary anterior teeth

o bjectives: correct determination of working length is an important step for suc- cess of endodontic therapy. conventional radiography has limitations in providing the accurate location of apical foramen. for this reason, electronic apex locators (eals) were developed to shorten the treatment time and decrease the radiation dose. the aim of this study was to evaluate the accuracy of root zx ea...

متن کامل

An in vivo study of working length determination with a new apex locator.

The success of an endodontic treatment relies on a correct working length determination. The canal terminus must be detected accurately and a precise control of the working length during the endodontic treatment must be maintained. The aim of this study was to investigate the working length determination in vivo with the Quill Apex Locator® for apical limit established at 1 mm short from the ap...

متن کامل

A Comparative Evaluation of Accuracy of New-generation Electronic Apex Locator with Conventional Radiography to determine Working Length in Primary Teeth: An in vivo Study

AIMS The purpose of this study was to evaluate the accuracy of a new-generation electronic apex locator (iPex) to determine working length in primary teeth with or without root resorption as compared with the conventional radiographic method. MATERIALS AND METHODS A sample of 30 primary posterior teeth which are indicated for pulpectomy were selected for the study. After obtaining the informe...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Dentistry 3000

سال: 2014

ISSN: 2167-8677

DOI: 10.5195/d3000.2014.26