New data for the definition of neutron beams for Boron Neutron capture therapy

نویسندگان

چکیده

Boron Neutron Capture Therapy (BNCT) is neutron radiotherapy used to treat tumours cells previously doped with Boron-10. This therapy requires an epithermal beam for the treatment of deep and a thermal shallow ones. Thanks recent high-current commercial accelerators, Accelerator-Based Sources (ABNS) are competitive option providing therapeutic beams in hospitals. In this work, field generated by 7Li (p,n)7Be reaction at 1950 keV studied as source ABNS, being measured Time-Of-Flight (TOF) technique HiSPANoS facility (Spain). Moreover, two Beam Shaping Assemblies (BSA) tumour treatment, which specially designed field, evaluated BNCT via Monte Carlo simulations (MCNP). Results agreement International Atomic Energy Agency (IAEA) figures merit endorse use BNCT.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

Boron Neutron Capture Therapy

A project aimed at the development of an accelerator facility devoted to Boron Neutron Capture Therapy (BNCT) is ongoing at the National Atomic Energy Commission of Argentina [1]. In a first stage of development, the accelerator will be capable of delivering proton or deuteron beams of 30 mA at about 1.4 MeV which is suitable for neutron production through the 9Be(d,n) reaction. In this context...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

متن کامل

Neutron Tube Design Study for Boron Neutron Capture Therapy Application

Radio-frequency (RF) driven ion sources are being developed in Lawrence Berkeley National Laboratory (LBNL) for sealed-accelerator-tube neutron generator application. By using a 5-cm-diameter RF-driven multicusp source H yields over 95% have been achieved. These experimental findings will enable one to develop compact neutron generators based on the D-D or D-T fusion reactions. In this new neut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiation Physics and Chemistry

سال: 2021

ISSN: ['1879-0895', '0969-806X']

DOI: https://doi.org/10.1016/j.radphyschem.2021.109474