Insertion Device Controls at the Swiss Light Source
In the initial phase of the Swiss Light Source (SLS), four insertion devices (ID) will be installed for the first four beamlines. The control system for all the ID’s follows, where possible, a uniform concept to allow a rapid installation schedule, while at the same time allowing for a variety in operational requirements. The components of the control system include the gap drive system with en...
متن کاملInsertion Device Controls at the Swiss Light Source
In the initial phase of the Swiss Light Source, four insertion devices (ID) will be installed for the first four beam-lines. The control system for all the ID's follows, where possible, an uniform concept to allow a rapid installation schedule, while at the same time allowing for a variety in operational requirements. The components of the control system include the gap drive system with encode...
متن کاملA beamline for high-pressure studies at the Advanced Light Source with a superconducting bending magnet as the source.
A new facility for high-pressure diffraction and spectroscopy using diamond anvil high-pressure cells has been built at the Advanced Light Source on beamline 12.2.2. This beamline benefits from the hard X-radiation generated by a 6 T superconducting bending magnet (superbend). Useful X-ray flux is available between 5 keV and 35 keV. The radiation is transferred from the superbend to the experim...
متن کاملChemical Crystallography at the Advanced Light Source
Chemical crystallography at synchrotrons was pioneered at the Daresbury SRS station 9.8. The chemical crystallography beamlines at the Advanced Light Source seek to follow that example, with orders of magnitude more flux than a lab source, and various in situ experiments. This article attempts to answer why a chemist would require synchrotron X-rays, to describe the techniques available at the ...
متن کاملMagnetic Performance of Insertion Devices at the Advanced Photon Source
The insertion devices (IDs) at the Advanced Photon Source have been magnetically tuned to minimize the integrals of the field through the devices and to minimize the variation of those integrals with gap, with a goal of not perturbing the stored particle beam. Measurements of the particle beam motion as the ID gap was changed found that the closed-orbit distortion was better than the requiremen...