Neutron polarimetry using a polarized 3He cell for the aCORN experiment

نویسندگان

چکیده

The neutron polarization of the NG-C beamline at NIST Center for Neutron Research was measured as part aCORN beta decay experiment. transmission through a polarized 3He spin filter cell recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed direction in an eight-step sequence to account drifts. dependence on used calculate polarization. time dependent fit model which included spectrum, and losses from relaxation AFP-NMR. found be ${\mid}P_\mathrm{n}{\mid} \leq 4\times 10^{-4}$ with 90 % confidence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Method for Precision Cold Neutron Polarimetry Using a 3He Spin Filter

We present a new method for precision measurement of the capture flux polarization of a polychromatic (white), continuous cold neutron beam, polarized by a (3)He spin filter. This method allows an in situ measurement and does not require knowledge of the neutron beam wavelength distribution. We show that a polarimetry precision of 0.1 % is possible.

متن کامل

Polarized 3He Spin Filters for Slow Neutron Physics

Polarized (3)He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background,...

متن کامل

Neutron beam effects on spin-exchange-polarized 3He.

We have observed depolarization effects when high intensity cold neutron beams are incident on alkali-metal spin-exchange-polarized 3He cells used as neutron spin filters. This was first observed as a reduction of the maximum attainable 3He polarization and was attributed to a decrease of alkali-metal polarization, which led us to directly measure alkali-metal polarization and spin relaxation o...

متن کامل

Determination of the neutron electric form factor in quasielastic scattering of polarized electrons from polarized 3He.

We report a measurement of the asymmetry in spin-dependent quasielastic scattering of longitudinally polarized electrons from a polarized 3 ~ e gas target. The asymmetry is measured at kinematics sensitive to the transverse-longitudinal response function R T L , ( Q ~ , ~ ) . The value of the neutron electric form factor G2 (Q' =0.16 (GeVlc) 2 , = + 0.070 zk 0.100 5 0.035 is extracted from the ...

متن کامل

In situ polarized 3He system for the Magnetism Reflectometer at the Spallation Neutron Source.

We report on the in situ polarized (3)He neutron polarization analyzer developed for the time-of-flight Magnetism Reflectometer at the Spallation Neutron Source at Oak Ridge National Laboratory. Using the spin exchange optical pumping method, we achieved a (3)He polarization of 76% ± 1% and maintained it for the entire three-day duration of the test experiment. Based on transmission measurement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research

سال: 2021

ISSN: ['1872-9576', '0168-9002']

DOI: https://doi.org/10.1016/j.nima.2020.164862