Neutron imaging with a micromegas detector
نویسندگان
چکیده
منابع مشابه
Simulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملMicromegas Detector for the Cast Experiment
A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection (5 × 10 −5 counts keV −1 cm −2 s −1) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in ...
متن کاملMicromegas for imaging calorimetry
Gaseous detectors have been used in sampling calorimeters for several years and still remain an attractive option for future collider experiments. The use of Micromegas chambers as active elements of a hadronic calorimeter was proposed a few years ago and stirred up exciting developments of this technology. Basic building blocks of large size chambers acting as signal generating and processing ...
متن کاملThe Micromegas detector of the CAST experiment
A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 × 10 −5 counts keV −1 cm −2 s −1) without shielding.
متن کاملPerformance of the Micromegas detector in the CAST experiment
The gaseous Micromegas detector designed for the CERN Axion search experiment CAST, operated smoothly during Phase-I, which included the 2003 and 2004 running periods. It exhibited linear response in the energy range of interest (1-10keV), good spatial sensitivity and energy resolution (15-19% FWHM at 5.9 keV) as well as remarkable stability. The detector’s upgrade for the 2004 run, supported b...