Neutron dose estimation via LET spectrometry using CR-39 detector for the reaction9Be (p, n)
نویسندگان
چکیده
منابع مشابه
Proton beam dosimetry by CR-39 track-etched detector
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
متن کاملInvestigating Indoor Radon Concentration Using CR-39 Detector; a Case Study of Gachin Dwellings in Hormozgan
Introduction: Radon is a colorless inert gas which decay products are the main component of natural radioactive elements that are naturally produced in under layers of earth crust by decay of radium and uranium. It enters through buildings via gaps and cracks. Radon gas decay products like alpha particle can increase the incidence of lung cancer in human. Since every person sp...
متن کاملStudy of Neutron Induced Modification on Optical Band Gap of CR-39 Polymeric Detector
Neutronirradiation effects on optical absorption of solid-state nuclear track detector, CR-39 was studied for the various fluences ranging from 2.38x106 to 2.7x108 n/cm by ultraviolet-visible (UVVis) spectroscopy. The optical absorption spectra in the wavelength range of 200-700nm were recorded for the pristine and the neutron irradiated samples in the above fluence range. The UV-visible spectr...
متن کاملA parameterization of nuclear track profiles in CR-39 detector
In this work, the empirical parameterization describing the alpha particles’ track depth in CR-39 detectors is extended to describe longitudinal track profiles against etching time for protons and alpha particles. MATLAB based software is developed for this purpose. The software calculates and plots the depth, diameter, range, residual range, saturation time, and etch rate versus etching time. ...
متن کاملEstimation of neutron effective dose from DD and DT neutron generators and the design of appropriate shield for standing user
Neutron Generators (NG) are used as a neutron source for different applications. During recent years, major efforts are underway to develop a high yield compact NG. In this way, radiation protection aspects need to be considered during the operation of these high yield NGs. In this paper the neutron effective dose of a NG operator has been calculated using MCNPX Monte Carlo code. The results sh...