Neutral-Carrier-Type Potassium Ion-Selective Electrodes Based on Polymer-supported Liquid-Crystal Membranes for Practical Use

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neutral-carrier-type potassium ion-selective electrodes based on polymer-supported liquid-crystal membranes for practical use.

Polymer-supported liquid-crystal membranes have been designed for neutral-carrier-type potassium ion-selective electrodes, aiming for practical applications of high-performance liquid-crystalline membrane ion sensors. Two types of polymer-supported liquid-crystal membranes were tested for their usefulness; one is microporous poly(tetra fluoroethylene) (PTFE) membranes impregnated by thermotropi...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

Use of highly hydrophobic ionic liquids for ion-selective electrodes of the liquid membrane type.

The phase-boundary potential at the interface between an aqueous KCl solution (W) and a hydrophobic room-temperature ionic liquid (RTIL), trioctylmethylammonium bis(nonafluorobutylsulfonyl)imide ([TOMA(+)][C(4)C(4)N(-)]), containing dicyclohexano-18-crown-6 (DCH18C6), shows the nernstian response to K(+) in W within a polarized potential window of 500 mV between [TOMA(+)][C(4)C(4)N(-)] and W, d...

متن کامل

Ion Activity Scales for Use with Selective Ion-sensitive Electrodes

The development of a variety of selective ion-sensitive electrodes focuses attention on numerical scales for the activity of individual ionic species, for these electrodes measure the activity of the selected ion only relative to that of the same species in a reference solution of known or assigned ion activity. Nevertheless, scales of ion activity must be based on a convention from outside the...

متن کامل

Miniaturizable Ion-Selective Arrays Based on Highly Stable Polymer Membranes for Biomedical Applications

Poly(vinylchloride) (PVC) is the most common polymer matrix used in the fabrication of ion-selective electrodes (ISEs). However, the surfaces of PVC-based sensors have been reported to show membrane instability. In an attempt to overcome this limitation, here we developed two alternative methods for the preparation of highly stable and robust ion-selective sensors. These platforms are based on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2004

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.20.1165