Sevoflurane does not increase intracranial pressure in hyperventilated dogs.
We have measured the effects of 0.5, 1.0 and 1.5 MAC (minimum alveolar concentration) end-tidal concentrations of sevoflurane on intracranial pressure (ICP), cerebral perfusion pressure (CPP), mean arterial pressure (MAP), central venous pressure and heart rate in hypocapnic dogs (PaCO2 3.2-3.7 kPa) and compared the data with those produced by equi-MAC concentrations of enflurane and halothane....
متن کاملAdvances in neurosonology 2005.
Most notable research with neurovascular ultrasound in 2005 focused on treatment amplification,1–3 identification of high-risk patients with intracranial stenoses,4 increased carotid intima-media thickness,5,6 monitoring repairs of ascending aorta,7 carotid stenting,8,9 patient selection and outcomes with percutaneous patent foramen ovale closure,10 and acute stroke treatment.11–15 Clopidogrel ...
متن کاملStandards in neurosonology. Part I
The paper presents standards related to ultrasound imaging of the cerebral vasculature and structures. The aim of this paper is to standardize both the performance and description of ultrasound imaging of the extracranial and intracranial cerebral arteries as well as a study of a specific brain structure, i.e. substantia nigra hyperechogenicity. The following aspects are included in the descrip...
متن کاملProtective Effect of N-Acetylcysteine Amide on Blast-Induced Increase in Intracranial Pressure in Rats
Blast-induced traumatic brain injury is associated with acute and possibly chronic elevation of intracranial pressure (ICP). The outcome after TBI is dependent on the progression of complex processes which are mediated by oxidative stress. So far, no effective pharmacological protection against TBI exists. In this study, rats were exposed to a single or repetitive blast overpressure (BOP) at mo...
متن کاملIntracranial pressure monitoring.
Recent studies have demonstrated that bedside cranial burr hole and insertion of intraparenchymal catheters for intracranial pressure monitoring performed by intensive care physicians is a safe procedure, with a complication rate comparable to other series published by neurosurgeons. The overall morbidity rate is comparable to, or even lower than, that caused by central vein catheterization. Th...