NERVE MEMBRANE CURRENT NOISE: DIRECT MEASUREMENTS UNDER VOLTAGE CLAMP
نویسندگان
چکیده
منابع مشابه
Current-Voltage Relations in the Lobster Giant Axon Membrane Under Voltage Clamp Conditions
The sucrose-gap method introduced by Stämpfli provides a means for the application of a voltage clamp to the lobster giant axon, which responds to a variety of different experimental procedures in ways quite similar to those reported for the squid axon and frog node. This is particularly true for the behavior of the peak initial current. However, the steady state current shows some differences....
متن کاملMembrane conductance and current-voltage relation in the squid axon under voltage-clamp.
,4BSTRACT TASAKI, I. AND C. S. SPYROPOULOS. Membrane conductance and currentvoltage relation in the squid axon under ‘voltage-clamp.’ &L-The conductance of the squid axon membrane under ‘voltage-clamp’ was measured by superposing a sinusoidal wave upon rectangular clamping voltage pulses. It was possible to determine the time course of the emf of the membrane under ‘voltage-clamp’ on a single p...
متن کاملVoltage and current clamp transients with membrane dielectric loss.
Transient responses of a space-clamped squid axon membrane to step changes of voltage or current are often approximated by exponential functions of time, corresponding to a series resistance and a membrane capacity of 1.0 muF/cm(2). Curtis and Cole (1938, J. Gen. Physiol.21:757) found, however, that the membrane had a constant phase angle impedance z = z(1)(jomegatau)(-alpha), with a mean alpha...
متن کاملCurrent-voltage relations in the isolated giant axon of the cockroach under voltage-clamp conditions.
Our understanding of the ionic exchanges taking place at the nerve membrane during electrical activity has been greatly increased by the application of the voltageclamp technique. This experimental method consists of the application of a stepwise change in potential to a given area of membrane and the simultaneous measurement of the current flow produced by this given potential gradient. The vo...
متن کاملMicrofluidic cell fusion under continuous direct current voltage
The authors report a technique which produces cell-to-cell electrofusion using a common direct current power supply on a microfluidic platform. In the authors’ method, the cells were first conjugated based on biotin-streptavidin interaction. The electrofusion was then conducted by flowing the linked cells through a simple microfluidic channel with geometric variation under continuous direct cur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Proceedings of the National Academy of Sciences
سال: 1969