Neonatal magnification radiography using standard-focus x-ray tubes
نویسندگان
چکیده
منابع مشابه
Visualization of neonatal lung injury associated with mechanical ventilation using x-ray dark-field radiography.
Mechanical ventilation (MV) and supplementation of oxygen-enriched gas, often needed in postnatal resuscitation procedures, are known to be main risk factors for impaired pulmonary development in the preterm and term neonates. Unfortunately, current imaging modalities lack in sensitivity for the detection of early stage lung injury. The present study reports a new imaging approach for diagnosis...
متن کاملLine focus x-ray tubes—a new concept to produce high brilliance x-rays
Currently hard coherent x-ray radiation at high photon fluxes can only be produced with large and expensive radiation sources, such as 3[Formula: see text] generation synchrotrons. Especially in medicine, this limitation prevents various promising developments in imaging and therapy from being translated into clinical practice. Here we present a new concept of highly brilliant x-ray sources, li...
متن کاملX-ray detectors for digital radiography.
Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital ra...
متن کاملStomach and duodenum: radiographic magnification using computed radiography (CR).
We performed direct radiographic magnification (X3) using a 0.1-mm microfocal tube and computed radiography (CR) in air-barium double-contrast studies of the stomach and duodenum. To eliminate blurring of the image due to motion, we used the maximum kilovolt peak rate possible (102 kVp), the maximum milliampere second rate possible (64 mAs), the shortest possible exposure time (0.1 second), and...
متن کاملPatient effective dose evaluation for chest X-ray examination in three digital radiography centers
Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Roentgenology
سال: 1983
ISSN: 0361-803X,1546-3141
DOI: 10.2214/ajr.141.4.665