Negative differential resistance in molecular junctions: Application to graphene ribbon junctions

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

, Observation of negative differential resistance in DNA molecular junctions

The mechanically controllable break junction technique is used to study charge transport through suspended DNA molecules. The current-voltage (I-V) characteristics in an aqueous solution display series of negative differential resistance (NDR) and hysteresis behavior. Under high-vacuum conditions, the peak positions of NDR shift to lower voltage, and the amplitude is reduced dramatically. The o...

متن کامل

Interaction-induced negative differential resistance in asymmetric molecular junctions.

Combining insights from quantum chemistry calculations with master equations, we discuss a mechanism for negative differential resistance (NDR) in molecular junctions, operated in the regime of weak tunnel coupling. The NDR originates from an interplay of orbital spatial asymmetry and strong electron-electron interaction, which causes the molecule to become trapped in a nonconducting state abov...

متن کامل

Room-temperature negative differential resistance in nanoscale molecular junctions

Molecular devices are reported utilizing active self-assembled monolayers containing the nitroamine @28-amino-4,48-di~ethynylphenyl!-58-nitro-1-benzenethiolate# or the nitro compound @4,48-di~ethynylphenyl!-28-nitro-1-benzenethiolate# as the active components. Both of these compounds have active redox centers. Current–voltage measurements of the devices exhibited negative differential resistanc...

متن کامل

Hysteresis, switching, and negative differential resistance in molecular junctions: a polaron model.

Within a simple mean-field model (self-consistent Hartree approximation) we discuss the possibility of polaron formation on a molecular wire as a mechanism for negative differential resistance (NDR), switching, and/or hysteresis in the I-V characteristic of molecular junctions. This mechanism differs from earlier proposed mechanisms of charging and conformational change. The polaron model captu...

متن کامل

Measurements of contact specific low-bias negative differential resistance of single metalorganic molecular junctions.

Negative differential resistance (NDR) behaviors of single molecule junctions composed of a thiol-terminated Ru(ii) bis-terpyridine (Ru(tpy-SH)2) molecule sandwiched between two gold electrodes are measured using a specifically modified scanning probe microscope break junction technique (SPMBJ) at room temperature. The low-bias (0.623 ± 0.135 V) NDR observed for one of the three conductance gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review B

سال: 2008

ISSN: 1098-0121,1550-235X

DOI: 10.1103/physrevb.78.085123