منابع مشابه
Six-axis vibration isolation technology applied to spaceborne interferometers
This paper discusses the vibration isolation problem as it applies to spaceborne interferometers, and presents evidence that vibration isolation will be a required technology fol these instruments. A hardware solution to the spaceborne interferometer isolation problem is offered with experimental evidence of its effectiveness.
متن کاملLinear Parameter-varying Control for Active Vibration Isolation Systems with Stiffness Hysteresis
We consider the use of linear parameter-varying methods for the control of stiffness hysteresis in vibration isolation systems. We assume that the hysteresis model is known, and we describe it using a stiffness parameter that takes values in a compact convex set. The proposed parameter-dependent controller is continuously scheduled based on real-time measurements or estimates of the stiffness, ...
متن کاملRelieving the effect of static load errors in nonlinear vibration isolation mounts through stiffness asymmetries
High Static Low Dynamic Stiffness (HSLDS) mounts consist of nonlinear springs that support a high static load with low static displacement, whilst maintaining locally low stiffness near equilibrium, to give a low natural frequency and consequently good isolation properties. Recent analysis has investigated such devices when the force-displacement relationship is an odd function about the equili...
متن کاملNanotechnology as general purpose technology
Scientific literature postulates that nanotechnology is to be considered as general purpose technology (GPT), characterized by pervasiveness, high technological dynamism and the inducement of innovations within a variety of applications. We set out to not only further systematize existing approaches investigating nanotechnology’s GPT traits based on patent applications, but to extend the analys...
متن کاملVibration Isolation for Scanning Tunneling Microscopy
Scanning Tunneling Microscopy measures tunneling current from conducting surfaces. Through analysis, it is possible to make a three dimensional picture accurate on an atomic scale of a surface and probe microscopic phenomenon. The procedure is dependent on the distance between the surface of the microscope tip and the sample surface. High tolerances on a scale less than an angstrom are required...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy Today
سال: 2007
ISSN: 1551-9295,2150-3583
DOI: 10.1017/s1551929500051002