Nebulised salbutamol

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prolonged hypoxaemia after nebulised salbutamol.

Pulse oximetry is increasingly used to assess hypoxaemia in respiratory illnesses. Six children presenting with acute asthma and prolonged falls in oxygen saturation values after treatment with salbutamol are described who were subsequently shown to have pneumonic consolidation on chest radiography.

متن کامل

nebulised salbutamol in patients with stable asthma

The influence of breathing pattern on lung deposition and bronchodilator response to nebulised salbutamol is uncertain. Three different breathing patterns were assessed in eight patients with chronic stable asthma. Salbutamol solution (2 5 mg in 4 ml) mixed with technetium-99m labelled human serum albumin was nebulised by an Acorn nebuliser at a flow rate of6 litres a minute. Particles with a m...

متن کامل

Nebulised ipratropium and salbutamol in asthma.

Treatment with nebulised salbutamol or a mixture of salbutamol and ipratropium was given to 138 children. Length of hospital stay and number of nebulised doses required did not differ. In severe asthma response was greater with salbutamol alone. In mild asthma response was greater with combined treatment.

متن کامل

Air or oxygen as driving gas for nebulised salbutamol.

The effects of nebulised salbutamol driven by compressed air or oxygen were compared in a randomised crossover study during 27 attacks of acute asthma. Arterial oxygen saturation fell by 2-6% during or after treatment in 10 cases: seven with compressed air, two with oxygen, and one with both driving gases. Hypoxaemia occurred in younger children and in those who fell asleep, but was not related...

متن کامل

Children with asthma: will nebulised salbutamol reduce hospital admissions?

To find out how many children with acute asthma responded to one or two doses of nebulised salbutamol and whether this response could be predicted 100 children were studied prospectively from two district hospitals. Twenty three children needed only one nebulised dose and 19 responded to two. Significant factors differentiating these responders from the remainder were age (24 (63%) of those age...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thorax

سال: 1981

ISSN: 0040-6376

DOI: 10.1136/thx.36.4.320