Near threshold pulse shape discrimination techniques in scintillating CsI(Tl) crystals

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near Threshold Pulse Shape Discrimination Techniques in Scintillating CsI(Tl) Crystals

There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. One of the major experimental challenges is to differentiate nuclear recoil signatures from the background β/γ-events due to ambient radioactivity on the basis of their different pulse shapes in the domain where the light output is close to the detection threshold. Using data derived from measurements wi...

متن کامل

An Embedded Microprocessor Design for the Pulse Shape Discrimination of a Plastic Scintillating Neutron Detector

Kaua‘i Community College (Kaua‘i CC) is presently participating in an effort to develop a space industry in Hawai‘i. This effort includes future launches of University of Hawai‘i supported micro-class satellites from the Pacific Missile Range Facility at Barking Sands, Kaua‘i. Kaua‘i CC’s participation is represented by operation and maintenance of a ground station, located on campus, to suppor...

متن کامل

Radiation damage in scintillating crystals

Crystal Calorimetry in future high-energy physics experiments faces a new challenge to maintain its precision in a hostile radiation environment. This paper discusses the effects of radiation damage in scintillating crystals, and concludes that the predominant radiation damage effect in crystal scintillators is the radiation-induced absorption, or color center formation, not the loss of scintil...

متن کامل

Pulse-shape discrimination with PbWO4 crystal scintillators

The light output, α/β ratio, and pulse shape have been investigated at −25◦ C with PbWO4 crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast 0.01 − 0.06 μs and middle 0.1 − 0.5 μs components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times 1− 3 μs and 13− 28 μs with the total intensity up to ≈ 50% have b...

متن کامل

Pulse-shape discrimination of La halide scintillators

The bright scintillators LaCl3:Ce and LaBr3:Ce were tested for a–g pulse-shape discrimination (PSD). PSD is demonstrated for LaCl3:Ce but not for LaBr3:Ce: r 2005 Elsevier B.V. All rights reserved.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 2004

ISSN: 0168-9002

DOI: 10.1016/j.nima.2003.12.024