Near-infrared transmittance pulse oximetry with laser diodes
نویسندگان
چکیده
منابع مشابه
Near-infrared transmittance pulse oximetry with laser diodes.
Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up of the optical sensor, sensor electronics, and processing block. Also, we show ...
متن کاملEffects of intravenously administered indocyanine green on near-infrared cerebral oximetry and pulse oximetry readings
BACKGROUND Intravenously administered indocyanine green (ICG) may cause misreadings of cerebral oximetry and pulse oximetry in patients undergoing carotid endarterectomy under general anesthesia. The present study determined the effects of two different doses (12.5 mg vs. 25 mg) of ICG on regional cerebral tissue oxygen saturation (SctO2) and percutaneous peripheral oxygen saturation (SpO2). ...
متن کاملCorn Density Measurement by Near-infrared Transmittance
A corn density calibration was developed for a near-infrared transmittance instrument (Infratec 1225). The calibration sample set included 96 corn samples grown in various locations of the United States. Samples were selected by principal component analysis (PCA) from a larger set of 410 samples, representing the 1986 through 1992 crop years. Samples for instrument and temperature stabilization...
متن کاملPulse Testing Of Laser Diodes
L-I-V Testing Basic Light intensity-Current-Voltage (L-I-V) testing is an I-V test with the addition of optical power measurements. This test is primarily used to sort laser diodes or weed out bad devices before they become part of an assembly. The device under test (DUT) is subjected to a current sweep while the forward voltage drop is recorded for each step in the sweep. Simultaneously, instr...
متن کاملPulse Oximetry
The principal advantage of optical sensors for medical applications is their intrinsic safety since there is no electrical contact between the patient and the equipment. (An added bonus is that they are also less suspect to electromagnetic interference). This has given rise to a variety of optical techniques to monitor physiological parameters: for example, the technique of Laser Doppler veloci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomedical Optics
سال: 2003
ISSN: 1083-3668
DOI: 10.1117/1.1578495