Near infra-red Mueller matrix imaging system and application to retardance imaging of strain
نویسندگان
چکیده
منابع مشابه
Application of Ensemble Learning Ica to Infra-red Imaging
James W. Miskin and David J. C. Ma Kay Cavendish Laboratory, Cambridge CB3 0HE, UK jwm1003 mrao. am.a .uk ABSTRACT We apply Independent Component Analysis methods to redu e a large data set of 2160 spe tra. The data were obtained by s anning an Infra-Red (THz) laser beam a ross a ross se tion of a tooth. We show that a Bilinear De omposition an represent the 2160 spe tra by a redu ed basis of a...
متن کاملA hematoma detector—a practical application of instrumental motion as signal in near infra-red imaging
In this paper we discuss results based on using instrumental motion as a signal rather than treating it as noise in Near Infra-Red (NIR) imaging. As a practical application to demonstrate this approach we show the design of a novel NIR hematoma detection device. The proposed device is based on a simplified single source configuration with a dual separation detector array and uses motion as a si...
متن کاملA frequency multiplexed near infra-red topography system for imaging functional activation in the brain
we have developed a novel near-infrared optical topography system that can acquire images at 10 frames per second. Sixteen laser diode sources (at 785 and 850 nm) are illuminated simultaneously, and each of 8 avalanche photodiode detectors records light from multiple sources. In this system, the contribution from each source is demultiplexed in software using fast Fourier transforms. This allow...
متن کاملSnapshot retinal imaging Mueller matrix polarimeter
Early diagnosis of glaucoma, which is a leading cause for visual impairment, is critical for successful treatment. It has been shown that Imaging polarimetry has advantages in early detection of structural changes in the retina. Here, we theoretically and experimentally present a snapshot Mueller Matrix Polarimeter fundus camera, which has the potential to record the polarization-altering chara...
متن کاملMueller Matrix Imaging Polarimeter for UV Metrology
The University of Arizona Polarization Laboratory with support from the Jet Propulsion Laboratory (JPL) has assembled and is currently calibrating a UV Mueller matrix imaging polarmeter (UV-MMIP). The desire for more accurate polarimetric and radiometric sensors drives the need for stringent polarization requirements and the ability to more precisely measure system and component polarization be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thin Solid Films
سال: 2011
ISSN: 0040-6090
DOI: 10.1016/j.tsf.2010.12.093