Navigated Pattern Laser System Versus Single-Spot Laser System for Postoperative Laser Retinopexy
نویسندگان
چکیده
منابع مشابه
Navigated Pattern Laser System versus Single-Spot Laser System for Postoperative 360-Degree Laser Retinopexy
Purpose. To compare three 360°-laser retinopexy (LRP) approaches (using navigated pattern laser system, single-spot slit-lamp (SL) laser delivery, and single-spot indirect ophthalmoscope (IO) laser delivery) in regard to procedure duration, procedural pain score, technical difficulties, and the ability to achieve surgical goals. Material and Methods. Eighty-six rhegmatogenous retinal detachment...
متن کاملSingle-frequency Pulsed Laser Oscillator and System for Laser-ultrasonics
We present a new pulsed laser oscillator and system for the optical detection of ultrasound in materials. A single-frequency laser oscillator based on a pulse pumped Nd:YAG rod inside a ring cavity is proposed. The laser delivers single-frequency pulses of 35 W power. Power of about 1 kW can be obtained when the second rod of a dual-rod pumping chamber is used as an amplifier. Performance of th...
متن کاملبررسی و مقایسه اثر q-switched nd yag laser و erbium laser در درمان ضایعات پیگمانته
هدف: این مطالعه به منظور بررسی و مقایسه اثر q-switched nd yag laser و erbium laser در درمان ضایعات پیگمانته انجام شده است. روش مطالعه: 116 فرد مبتلا به ضایعات پیگمانته از نوع فرکل و خال وارد مطالعه شدند که 58 مورد با استفاده از q-switched nd yag laser و 58 مورد با لیزر erbium درمان شدند و در نهایت میزان اثربخشی (از بین رفتن کامل ضایعات) در دو گروه تعیین و مقایسه گردید. یافته ها: در این مطالعه...
15 صفحه اولLaser scanning laser diode photoacoustic microscopy system
The development of low-cost and fast photoacoustic microscopy systems enhances the clinical applicability of photoacoustic imaging systems. To this end, we present a laser scanning laser diode-based photoacoustic microscopy system. In this system, a 905 nm, 325 W maximum output peak power pulsed laser diode with 50 ns pulsewidth is utilized as the light source. A combination of aspheric and cyl...
متن کاملLaser Soldering of Rat Skin Using a Controlled Feedback System
Introduction: Laser tissue soldering using albumin and indocyanine green dye (ICG) is an effective technique utilized in various surgical procedures. The purpose of this study was to perform laser soldering of rat skin under a feedback control system and compare the results with those obtained using standard sutures. Material and Methods: Skin incisions were made over eight rats’ dorsa, which w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ophthalmology in Russia
سال: 2019
ISSN: 2500-0845,1816-5095
DOI: 10.18008/1816-5095-2019-3-296-303