Nanoliter Multiplex PCR Arrays on a SlipChip

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanoliter multiplex PCR arrays on a SlipChip.

The SlipChip platform was tested to perform high-throughput nanoliter multiplex PCR. The advantages of using the SlipChip platform for multiplex PCR include the ability to preload arrays of dry primers, instrument-free sample manipulation, small sample volume, and high-throughput capacity. The SlipChip was designed to preload one primer pair per reaction compartment and to screen up to 384 diff...

متن کامل

Digital PCR on a SlipChip.

This paper describes a SlipChip to perform digital PCR in a very simple and inexpensive format. The fluidic path for introducing the sample combined with the PCR mixture was formed using elongated wells in the two plates of the SlipChip designed to overlap during sample loading. This fluidic path was broken up by simple slipping of the two plates that removed the overlap among wells and brought...

متن کامل

SlipChip for immunoassays in nanoliter volumes.

This article describes a SlipChip-based approach to perform bead-based heterogeneous immunoassays with multiple nanoliter-volume samples. As a potential device to analyze the output of the chemistrode, the performance of this platform was tested using low concentrations of biomolecules. Two strategies to perform the immunoassay in the SlipChip were tested: (1) a unidirectional slipping method t...

متن کامل

Petri dish PCR: laser-heated reactions in nanoliter droplet arrays.

We report high-speed real-time PCR performed on an unmodified disposable polystyrene Petri dish. The reaction cycle relies solely on an infrared laser for heating; no conventional heater is required. Nanoliter droplets of PCR mixture as water-in-oil emulsions printed in an array format served as individual PCR microreactors. A simple contact printing technique was developed to generate a large ...

متن کامل

User-loaded SlipChip for equipment-free multiplexed nanoliter-scale experiments.

This paper describes a microfluidic approach to perform multiplexed nanoliter-scale experiments by combining a sample with multiple different reagents, each at multiple mixing ratios. This approach employs a user-loaded, equipment-free SlipChip. The mixing ratios, characterized by diluting a fluorescent dye, could be controlled by the volume of each of the combined wells. The SlipChip design wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Chemistry

سال: 2010

ISSN: 0003-2700,1520-6882

DOI: 10.1021/ac1007249