Nanoliter contact angle probes tumor angiogenic ligand–receptor protein interactions
نویسندگان
چکیده
منابع مشابه
Discovering Domains Mediating Protein Interactions
Background: Protein-protein interactions do not provide any direct information regarding the domains within the proteins that mediate the interactions. The majority of proteins are multi domain proteins and the interaction between them is often defined by the pairs of their domains. Most of the former studies focus only on interacting domain pairs. However they do not consider the in...
متن کاملMethylphosphonates as probes of protein-nucleic acid interactions.
Deoxydinucleoside methylphosphonates were prepared by chemical synthesis and were introduced stereospecifically into the lac operator at two sites. These sites within d(ApApTpTpGpTpGpApGpCpGpGpApTpApApCpApApTpT), segment I, and d(ApApTpTpGpTpTpApTpCpCpGpCpTpCpApCpApApTpT), segment II, are indicated by p. Each segment containing a chiral methylphosphonate was annealed to the complementary unmodi...
متن کاملChemical nucleases as probes for studying DNA-protein interactions.
Over the past fifteen years much research has been devoted to the mode(s) by which the linear DNA macromolecule communicates with cellular proteins in the course of genetic programming, thus determining the patterns of growth and development in living organisms. A plethora of proteins have been shown to interact non-covalently with DNA either as structural elements, exemplified by the histones ...
متن کاملContact interactions method: a new algorithm for protein folding simulations.
Computer simulations of simple exact lattice models are an aid in the study of protein folding process; they have sometimes resulted in predictions experimentally proved. The contact interactions (CI) method is here proposed as a new algorithm for the conformational search in the low-energy regions of protein chains modeled as copolymers of hydrophobic and polar monomers configured as self-avoi...
متن کاملWide-angle noncontact and small-angle contact cameras.
The theoretical wide-angle model of the human eye and the principle of separation of ophthalmoscopic illumination and observation apertures have been used to design two fundamentally different ophthalmoscopic cameras: a 90 degree wide-angle, noncontact camera and a high-resolution macula-disc camera. The chief advantage of the 90 degree noncontact camera is the increase in contrast achieved by ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biosensors and Bioelectronics
سال: 2010
ISSN: 0956-5663
DOI: 10.1016/j.bios.2010.07.115