Nanocomposite Magnetite-Kaolin for Rh Preconcentration and Determination by Electrothermal Atomic Absorption Spectrometry
نویسندگان
چکیده
منابع مشابه
Automated on-line separation–preconcentration system for platinum determination by electrothermal atomic absorption spectrometry
A flow injection on-line sorption preconcentration system for the electrothermal atomic absorption spectrometric determination of platinum has been developed. The method employs on-line preconcentration of platinum on a column packed with silica gel functionalised with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide (DPTH-gel) placed in the autosampler arm. The modification of the autosampler...
متن کاملPreconcentration of gallium by coprecipitation with synthetic zeolites prior to determination by electrothermal atomic absorption spectrometry.
Synthetic zeolites were dissolved in nitric acid, and the resulting solution used as a coprecipitant for the preconcentration of trace amounts of gallium in water samples prior to determination by electrothermal atomic absorption spectrometry (ETAAS). The gallium preconcentration conditions and the ETAAS measurement conditions were optimized. Gallium was quantitatively concentrated with the zeo...
متن کاملArsenic determination in naphtha by electrothermal atomic absorption spectrometry after preconcentration using multiple injections
Marcio V. Reboucas,* Sergio L. C. Ferreira and Benicio de Barros Neto Braskem S. A., Unidade de Insumos Básicos, Laboratório, Rua Eteno 1561, Complexo Petroquı́mico de Camacari, Camacari-Bahia, Brazil 42810-000. E-mail: [email protected] Universidade Federal da Bahia, Instituto de Quı́mica, Departamento de Quı́mica Analitica, Campus Universitário de Ondina, Salvador-Bahia, Brazil 4017...
متن کاملDetermination of cadmium in wine by electrothermal atomic absorption spectrometry.
A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2020
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.19san01