Myoclonic spasms after epidural diamorphine infusion
نویسندگان
چکیده
منابع مشابه
Diamorphine infusion in the preterm neonate.
The effects of diamorphine were studied in 34 premature neonates who were given a loading dose of 50 micrograms/kg of diamorphine followed by a constant rate intravenous infusion of 15 micrograms/kg/hour. Small but significant falls were noted in blood pressure (at 30 minutes) and heart rate (at 30 minutes, six hours, and 12 hours) after administration of diamorphine, but these did not appear t...
متن کاملComparison of epidural methadone with epidural diamorphine for analgesia following caesarean section.
Analgesia provided by either 5 mg diamorphine, or 5 mg methadone administered by the epidural route during elective caesarean section was compared in 40 women. The median time to further analgesia in the methadone group was 395 min, and 720 min in the diamorphine group, P = 0.0003. Linear analogue scores to assess pain were measured 2-hourly for 12 h, then again at 24 h postoperatively. Pain sc...
متن کاملPostoperative analgesia by continuous extradural infusion of bupivacaine and diamorphine.
Three solutions administered by continuous extradural infusion for postoperative analgesia were compared in a randomized, double-blind manner. All patients underwent major abdominal gynaecological surgery and received 0.125% bupivacaine in 0.9% saline, diamorphine in 0.9% saline (0.5 mg in 15 ml) or diamorphine mixed with 0.125% bupivacaine (0.5 mg in 15 ml), at a rate of 15 ml h-1. The bupivac...
متن کاملReports of epidural infusion errors.
In the first case, a post-operative patient was prescribed fentanyl 2 mcg/mL with bupivacaine 0.125% by epidural infusion for pain management. The infusion rate ordered was 10 mL/hour. Ketorolac 30 mg intravenously was also prescribed for this patient. A student nurse ‘piggybacked’ a 50 mL minibag containing ketoralac to the main IV line which did not have an infusion pump. She then mistakenly ...
متن کاملAn isobolographic analysis of diamorphine and levobupivacaine for epidural analgesia in early labour.
BACKGROUND Few data describe the pharmacological interactions between local anaesthetics and opioids. The aim of this study was to measure the median effective concentration (MEC) of diamorphine and levobupivacaine when given separately and as mixtures for epidural analgesia, and determine whether the combination is additive or synergistic. METHODS One hundred and twenty patients were enrolle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 1991
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1991.tb11688.x