Myocardial ischaemia during tracheal intubation and extubation
نویسندگان
چکیده
منابع مشابه
Myocardial ischaemia during tracheal intubation and extubation.
The incidence of myocardial ischaemia during tracheal intubation and extubation was compared using ambulatory ECG monitoring in 60 patients undergoing a variety of different surgical operations. Seven patients had myocardial ischaemia after tracheal intubation and seven patients during tracheal extubation. The patients who developed myocardial ischaemia during tracheal extubation had significan...
متن کاملRespiratory complications associated with tracheal intubation and extubation.
We conducted a prospective survey on the incidence of respiratory complications associated with tracheal intubation and extubation in 1005 patients who underwent elective general anaesthesia over a 4-month period. During induction of anaesthesia, respiratory complications occurred in 46 patients (4.6%; 95% confidence limits (CL): 3.3, 5.9%). The common complications were coughing (1.5%) and dif...
متن کاملThe effect of an infusion of esmolol on the incidence of myocardial ischaemia during tracheal extubation following coronary artery surgery
The aim of this randomised controlled study was to determine whether an esmolol infusion affected the incidence of ST segment changes during weaning from intermittent positive pressure ventilation and tracheal extubation after coronary artery surgery. Thirty-one patients received an infusion of esmolol 0-300 microg x kg(-1) x min(-1) and 37 patients comprised the control group. ST segment chang...
متن کاملTracheal extubation.
Tracheal extubation in both the critical care and anesthesia setting is not only an important milestone for patient recovery, but also a procedure that carries a considerable risk of complication or failure. Mechanical ventilation is associated with significant complications that are time-dependent in nature, with a longer duration of intubation resulting in a higher incidence of complications,...
متن کاملDifficult tracheal extubation.
We describe a case of nasotracheal tube fixation with a screw. A second case is described in which a broken drill bit was found to impinge on the wall but not penetrate into the lumen of a nasotracheal tube. Possible sequelae of this complication include airway leak, aspiration, tube obstruction, and trauma from attempts at forceful extubation. We recommend the routine intraoperative testing fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Anaesthesia
سال: 1994
ISSN: 0007-0912
DOI: 10.1093/bja/73.4.537