Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array
نویسندگان
چکیده
منابع مشابه
Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.
Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth ...
متن کاملPhotoacoustic Microscopy and Photoacoustic Computed Tomography Using High-frequency Linear Array Ultrasonic Transducers
متن کامل
Tripling the detection view of high-frequency linear-array-based photoacoustic computed tomography by using two planar acoustic reflectors.
BACKGROUND Linear-array-based photoacoustic computed tomography (PACT) suffers from a limited view. Circular scanning does increase the detection view angle but is time-consuming. Therefore, it is desirable to increase the detection view angle of linear-array-based PACT without sacrificing imaging speed. METHODS Two planar acoustic reflectors placed at 120 degrees to each other were added to ...
متن کاملEnhancement of photoacoustic tomography by ultrasonic computed tomography based on optical excitation of elements of a full-ring transducer array.
Photoacoustic computed tomography (PACT) is a hybrid technique that combines optical excitation and ultrasonic detection to provide high-resolution images in deep tissues. In the image reconstruction, a constant speed of sound (SOS) is normally assumed. This assumption, however, is often not strictly satisfied in deep tissue imaging, due to acoustic heterogeneities within the object and between...
متن کاملPiezoelectric line detector array for photoacoustic tomography
Photoacoustic tomography relies on a dense coverage of the surface surrounding the imaged object with ultrasound sensors in order to enable an accurate reconstruction. A curved arrangement of integrating line sensors is proposed that is able to acquire data for a linear projection image of the absorbed energy density distribution in the object. Upon rotation of the object relative to the array,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomedical Optics
سال: 2015
ISSN: 1083-3668
DOI: 10.1117/1.jbo.20.6.066010