Multistorey Residential Building with Base Isolation Method Using SAP
نویسندگان
چکیده
منابع مشابه
Comparative Analysis of a Multistorey Building with and
Viscoelastic dampers are considered to be better than most of the passive energy dissipation devices. Researches done on the improvement of its performance for analyzing structures has always been in vogue. The significant change in the response of the structures to make it resistant to earthquake and wind forces is the main idea behind using such devices. A comparative analysis of a G+44 RCC s...
متن کاملStudy of Base-Isolation Building System
In order to improve the effect of isolation structure, the principles and behaviours of the base-isolation system are studied, and the types and characteristics of the base-isolation are also discussed. Compared to the traditional aseismatic structures, the base isolation structures decrease the seismic response obviously: the total structural aseismatic value decreases to 1/4-1/32 and the seis...
متن کاملAltitude Determination of a Pedestrian in a Multistorey Building
A challenging task in using pedestrian navigation and guidance services indoors is to determine the correct floor of a user in a multi-storey building because most indoor location techniques only provide 2-D information. In this case it can be recommended to augment the position determination system with a barometric pressure sensor for direct observation of height differences. In the research ...
متن کاملPounding Control of Structures Using Base Isolation
The most important property of a base-isolation system is to make the base more flexible than the elements of the superstructure, but it must still be stiff enough to resist typical pounding forces, wind loadings, and similar low-amplitude horizontal forces. However, the potential consequences of earthquake-induced poundings on seismically isolated buildings can be much more substantial, and, t...
متن کاملAutomatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection
A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency) earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Engineering & Technology
سال: 2018
ISSN: 2227-524X
DOI: 10.14419/ijet.v7i3.10.15637