Multiscale, multispectral fluorescence lifetime imaging using a double-clad fiber

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible endoscope for continuous in vivo multispectral fluorescence lifetime imaging.

Fluorescence lifetime imaging (FLIM) offers a noninvasive approach for characterizing the biochemical composition of biological tissue. There has been an increasing interest in the application of multispectral FLIM for medical diagnosis. Central to the clinical translation of FLIM technology is the development of compact and high-speed endoscopy systems. Unfortunately, the predominant multispec...

متن کامل

Handheld multispectral fluorescence lifetime imaging system for in vivo applications.

There is an increasing interest in the application of fluorescence lifetime imaging (FLIM) for medical diagnosis. Central to the clinical translation of FLIM technology is the development of compact and high-speed clinically compatible systems. We present a handheld probe design consisting of a small maneuverable box fitted with a rigid endoscope, capable of continuous lifetime imaging at multi...

متن کامل

Intravascular atherosclerotic imaging with combined fluorescence and optical coherence tomography probe based on a double-clad fiber combiner.

We developed a multimodality fluorescence and optical coherence tomography probe based on a double-clad fiber (DCF) combiner. The probe is composed of a DCF combiner, grin lens, and micromotor in the distal end. An integrated swept-source optical coherence tomography and fluorescence intensity imaging system was developed based on the combined probe for the early diagnoses of atherosclerosis. T...

متن کامل

Multispectral fluorescence imaging.

Multispectral fluorescence imaging (MSFI) is a rapidly growing field with broad applications in both preclinical and clinical settings. Application of this novel technology in small-animal imaging and microscopy produces enhanced sensitivity and reliable quantification and resolves multiple simultaneous signals. MSFI flow cytometry can quantify multiple fluorescent parameters with morphologic o...

متن کامل

Double-clad fiber with a tapered end for confocal endomicroscopy

We present a double-clad fiber coupler (DCFC) for use in confocal endomicroscopy to reduce speckle contrast, increase signal collection while preserving optical sectioning. The DCFC is made by incorporating a double-clad tapered fiber (DCTF) to a fused-tapered DCFC for achromatic transmission (from 1265 nm to 1325 nm) of > 95% illumination light trough the single mode (SM) core and collection o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Letters

سال: 2019

ISSN: 0146-9592,1539-4794

DOI: 10.1364/ol.44.002302