Fatigue Failure of Noncemented Porous-coated Implants
The causes of mechanical failure of five noncemented porous-coated components were studied. There were two cobalt-chromium alloy and three titanium alloy implants which fractured after 12 to 48 months. The implants included one acetabular component, and one femoral condylar, one patellar and two tibial components. Examination of the fractured surfaces revealed fatigue to be the mechanism of fai...
متن کاملFatigue failure of dental implants in simulated intraoral media.
Metallic dental implants are exposed to various intraoral environments and repetitive loads during service. Relatively few studies have systematically addressed the potential influence of the environment on the mechanical integrity of the implants, which is therefore the subject of this study. Four media (groups) were selected for room temperature testing, namely dry air, saliva substitute, sam...
متن کاملMultiscale cohesive failure modeling of heterogeneous adhesives
A novel multiscale cohesive approach that enables prediction of the macroscopic properties of heterogeneous thin layers is presented. The proposed multiscale model relies on the Hill’s energy equivalence lemma, implemented in the computational homogenization scheme, to couple the microand macro-scales and allows to relate the homogenized cohesive law used to model the failure of the adhesive la...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملEarly migration predicts late aseptic failure of hip sockets.
We report a prospective, stratified study of 60 PCA-cups and 60 RM-polyethylene cups which have been followed for a median time of 90 months, with annual radiography. The radiological migration of cups was measured by the computer-assisted EBRA method. A number of threshold migration rates from 1 mm in the first year to 1 mm in five years have been assessed and related to clinically determined ...