Multiscale Characterisation of Cortical Bone Tissue

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiscale Modelling of bioreactors for growing bone tissue

Failure to grow thick (3D) implantable bone tissue is partly due to the lack of tissue vascularisation resulting from a fall in nutrient supply to the cells as the distance between the cells and nutrient sources increases. Previous attempts that used porous scaffold without hollow fibre (HF) produced tissues of less than 0.5mm thickness which are of limited clinical use. Recent studies suggest ...

متن کامل

Analysis of fracture processes in cortical bone tissue

Bones are the principal structural components of a skeleton; they play unique roles in the body providing its shape maintenance, protection of internal organs and transmission of forces. Ultimately, their structural integrity is vital for the quality of life. Unfortunately, bones can only sustain loads until a certain limit, beyond which they fail. Understanding a fracture behaviour of bone is ...

متن کامل

Cortical Tissue Porosity of Brittle Osteogenesis Imperfecta Bone

INTRODUCTION There is currently no cure for the skeletal dysplasia osteogenesis imperfecta (OI), a debilitating disease that occurs in approximately 1 in every 20,000 human births. OI is caused by a genetic mutation that results in brittle bones and many fractures. In a mouse model of the disease, oim, we have characterized bone structure using X-ray microtomography, and found that oim bone has...

متن کامل

Soft-tissue and cortical-bone thickness at orthodontic implant sites.

INTRODUCTION To obtain sufficient stability of implants, the thickness of the soft tissue and the cortical bone in the placement site must be considered. However, the literature contains few anatomical studies of orthodontic implants. METHODS To measure soft-tissue and cortical-bone thicknesses, maxillae from 23 Korean cadavers were decalcified, and buccopalatal cross-sectional specimens were...

متن کامل

The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus.

The elastic moduli of human subchondral, trabecular, and cortical bone tissue from a proximal tibia were experimentally determined using three-point bending tests on a microstructural level. The mean modulus of subchondral specimens was 1.15 GPa, and those of trabecular and cortical specimens was 4.59 GPa and 5.44 GPa respectively. Significant differences were found in the modulus values betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Sciences

سال: 2019

ISSN: 2076-3417

DOI: 10.3390/app9235228