Multiport vector network analyzer calibration: a general formulation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Optimal Vector-Network-Analyzer Calibration Algorithm

We present an iterative algorithm for calibrating vector network analyzers based on orthogonal distance regression. The algorithm features a robust, yet efficient, search algorithm, an error analysis that includes both random and systematic errors, a full covariance matrix relating calibration and measurement errors, 95% coverage factors, and an easy-to-use user interface that supports a wide v...

متن کامل

A New Implementation of a Multiport Automatic Network Analyzer

A generalized multiport network analyzer implemented using commercially available hardware is presented. Measurement calibration is accomplished through a novel calibration procedure which requires only conventional standards used for two-port calibrations, The calibration theory accounts for the errors due to the signal switching network but does not systematically remove errors due to signal ...

متن کامل

On-Wafer Vector Network Analyzer Calibration and Measurements

The representative VNA block diagram (see Figure 1) shows the key elements of the analyzer. The RF source at the top provides the device-under-test (DUT) stimulus. A forward/reverse switch directs the RF energy to either DUT port. The test set uses directional couplers or bridges to pick off the forward and reverse waves traveling to and from each port, and down-converts these signals to four I...

متن کامل

Vector-Network-Analyzer Calibrations

We develop an uncertainty analysis that captures the dominant sources of measurement error in state-of-the-art WM-380 (WR 1.5) rectangular-waveguide vector-network-analyzer measurements over the frequency range 500–750 GHz. We use the analysis to assess thru-reflect-line, thru-short-match, and thru-short-radiating-open calibrations. The comparison shows that thru-short-match and thru-short-radi...

متن کامل

Calibration of a Metallic Access Network Analyzer

A calibration approach is proposed to compensate the systematic errors when the input reflection coefficient of a metallic access network cable is obtained using single port measurements from an access network analyzer. The analyzer is a versatile instrument and uses optimal cable matching and internal balancing to achieve maximum measurement resolution. The analyzer uses test-leads connected t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Microwave Theory and Techniques

سال: 1994

ISSN: 0018-9480

DOI: 10.1109/22.339781