Multiplying optical tweezers force using a micro-lever
نویسندگان
چکیده
منابع مشابه
Multiplying optical tweezers force using a micro-lever.
This study presents a photo-driven micro-lever fabricated to multiply optical forces using the two-photon polymerization 3D-microfabrication technique. The micro-lever is a second class lever comprising an optical trapping sphere, a beam, and a pivot. A micro-spring is placed between the short and long arms to characterize the induced force. This design enables precise manipulation of the micro...
متن کاملMicro-rheology on (polymer-grafted) colloids using optical tweezers.
Optical tweezers are experimental tools with extraordinary resolution in positioning (± 1 nm) a micron-sized colloid and in the measurement of forces (± 50 fN) acting on it-without any mechanical contact. This enables one to carry out a multitude of novel experiments in nano- and microfluidics, of which the following will be presented in this review: (i) forces within single pairs of colloids i...
متن کاملOptical lever calibration in atomic force microscope with a mechanical lever.
A novel method that uses a small mechanical lever has been developed to directly calibrate the lateral sensitivity of the optical lever in the atomic force microscope (AFM). The mechanical lever can convert the translation into a nanoscale rotation angle with a flexible hinge that provides an accurate conversion between the photodiode voltage output and torsional angle of a cantilever. During t...
متن کاملmeasuring viscoelastic properties of Red Blood Cell using optical tweezers
Efforts have been made to study the behavior of complex materials in micrometer dimensions with various techniques. One of these methods is the use of optical tweezers for biophysical applications. Red blood cells, as the most abundant blood-forming cells, play an important role in the life of living organisms, and their unique mechanical properties are important. In this report, the study of s...
متن کاملNoninvasive determination of optical lever sensitivity in atomic force microscopy
Atomic force microscopes typically require knowledge of the cantilever spring constant and optical lever sensitivity in order to accurately determine the force from the cantilever deflection. In this study, we investigate a technique to calibrate the optical lever sensitivity of rectangular cantilevers that does not require contact to be made with a surface. This noncontact approach utilizes th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2011
ISSN: 1094-4087
DOI: 10.1364/oe.19.020604