Multiplexed proteomic sample preconcentration device using surface-patterned ion-selective membrane
نویسندگان
چکیده
منابع مشابه
Capillary-valve-based fabrication of ion-selective membrane junction for electrokinetic sample preconcentration in PDMS chip.
In this paper, we report a novel method for fabricating ion-selective membranes in poly(dimethylsiloxane) (PDMS)/glass-based microfluidic preconcentrators. Based on the concept of capillary valves, this fabrication method involves filling a lithographically patterned junction between two microchannels with an ion-selective material such as Nafion resin; subsequent curing results in a high aspec...
متن کاملPaper-based ion concentration polarization device for selective preconcentration of muc1 and lamp-2 genes
Recently, novel biomolecules separation and detection methods based on ion concentration polarization (ICP) phenomena have been extensively researched due to its high amplification ratio and high-speed accumulation. Despite of these bright advances, the fabrication of conventional ICP devices still have complicated and times-consuming tasks. As an alternative platform, a paper have been recentl...
متن کاملPreconcentration of Zn(II) in Water Sample Using Modified NanoFiber
A new simple and reliable method for rapid and selective extraction and determination of trace levels of Zn(II) ion is developed. Zn(II) ions are adsorbed quantitatively during passage of aqueous samples through PET-AA/AAm nano fiber modified. Almost all matrix elements were found to pass through the nano fiber to drain. Modified Poly (ethylene terephthalate)-grafted-Acrylic acid/Acryl amide Na...
متن کاملPreconcentration of Zn(II) in Water Sample Using Modified NanoFiber
A new simple and reliable method for rapid and selective extraction and determination of trace levels of Zn(II) ion is developed. Zn(II) ions are adsorbed quantitatively during passage of aqueous samples through PET-AA/AAm nano fiber modified. Almost all matrix elements were found to pass through the nano fiber to drain. Modified Poly (ethylene terephthalate)-grafted-Acrylic acid/Acryl amide Na...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Lab on a Chip
سال: 2008
ISSN: 1473-0197,1473-0189
DOI: 10.1039/b717900f