Multiple pinhole collimator based X-ray luminescence computed tomography
نویسندگان
چکیده
منابع مشابه
Multiple pinhole collimator based X-ray luminescence computed tomography.
X-ray luminescence computed tomography (XLCT) is an emerging hybrid imaging modality, which is able to improve the spatial resolution of optical imaging to hundreds of micrometers for deep targets by using superfine X-ray pencil beams. However, due to the low X-ray photon utilization efficiency in a single pinhole collimator based XLCT, it takes a long time to acquire measurement data. Herein, ...
متن کاملCollimated superfine x-ray beam based x-ray luminescence computed tomography.
X-ray luminescence computed tomography (XLCT) is a hybrid imaging modality with the potential to achieve a spatial resolution up to several hundred micrometers for targets embedded in turbid media with a depth larger than several millimeters. In this paper, we report a high spatial resolution XLCT imaging system with a collimated superfine x-ray beam in imaging the deeply embedded targets. A co...
متن کاملX-ray luminescence computed tomography using a focused x-ray beam.
Due to the low x-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device camera setup, the collimator-based narrow beam x-ray luminescence computed tomography (XLCT) usually requires a long measurement time. We, for the first time, report a focused x-ray beam-based XLCT imaging system with measurements by a single optical fiber bundle ...
متن کاملX-ray computed tomography.
X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictio...
متن کاملX-ray micro-computed tomography
Micro-computed tomography (μCT) has been successfully used to study the cardiovascular system of mouse embryos in situ. With the use of barium as a suitablecontrast agent, blood vessels have beenimaged and analysed quantitatively such asblood volume and vessel sizes on embryosof ages 14.5 to 16.5 days old. The advantageof using this imaging modality is that it hasprovide...